Model UM12FDQNS3/MGC
Small right oven not heating. Neither bake nor broil. Called tech support. We took out the bottom drawer and stuck a pen inside a red button and did a reset. Now it heats great.
“On time, quick, efficient and effective.”
Don N.
Notes from real Omega Force service calls: the appliance, the problem we found and how we fixed it.
Repairs completed February 7, 2024 to February 12, 2024
Model UM12FDQNS3/MGC
Small right oven not heating. Neither bake nor broil. Called tech support. We took out the bottom drawer and stuck a pen inside a red button and did a reset. Now it heats great.
“On time, quick, efficient and effective.”
Don N.
Model AFNE9BSP116TW13
Disassembled front and rear of machine. Removed front tub cover and rear pulley. Pulled old tub assembly out and replaced it with new. Put everything back together. Ran all the way through a spin cycle and everything looked great. Balances much better now.
“Hyrum was great!! On time, explained everything and fixed our washing machine!!! Thank you!”
Brian H.
Model LDF7774BD
Returned with the part, installed the part, remounted the unit, cycled and tested, the unit now fills and drains as it should.
“My dishwasher was not working and Brandon, Omega’s technician, assessed the problem, ordered the part and a few days later the dishwasher was good as new! I certainly would recommend Omega Force Appliance Repair for anyone needing such a service.”
Patricia W.
Model KBFS20EVBL6
Customer complaint is, seems to be leaking from the ice maker area. Inspected and tested. FF temperature is 38F and freezer is 2F. The whole bottom of the freezer is covered in a sheet of ice. I disassembled freezer and found the evaporator defrost drain is plugged and frozen over. I completely defrosted freezer compartment and dried it out. Steamed out drain and now its draining.
“We were very pleased Matt solved our problem quickly and professionally”
Linda A.
Model WRF555SDHW01
The complaint was its not making ice. When I arrived I pulled the ice bucket out and it has ice in it. I removed the ice maker and there is water in the mold and its starting to freeze. I verified the ice maker thermistor passed and the ice maker fan is working. I took a freezer temp and it got down to 3.8 and I took a picture of it at 4.2 degrees. Both sections are cooling good. I replaced the water valve that was sent. No issues found.
Model WRB119WFBM00
Customer stated the fresh food part was warm the freezer was working fine.Found the freezer door was left open, steamed out the freezer, checked the drain, cleaned the dust off the bottom. Unit started cooling.
“Brandon was very friendly & helpful. He was very knowledgeable & worked very fast.”
Christine K.
Model GTD65GBSJ3WS
Replaced main control board and programmed personality ID. Testing machine and it seems to be running right now.
“When I called for service Hyrum was at the house within 2 hours to check out the problem. He was polite and knowledgeable. He wasted no time and got the needed part ordered. Omega kept in touch so I knew when the part came in. Hyrum was on time and my dryer was fixed with no issues. I will use Omega again.”
Jill C.
Model AWS17NW
Installed a new belt, and after testing, the cycle, spin, and drain all work great without any issues.
“Excellent! Very skilled and efficient! Great service! Promote this guy!”
Edward C.
Model DLE7000W.ABWEUUS
Customer stated the unit will run for about 10 minutes and trips the breaker, top of the unit gets very hot. Tested the outside vent for airflow speed and it is at 19 mph, got some bath towels wet and ran the unit on high heat, can hear the heater cycling, tripped the breaker at 149 degrees. 21 amps. Reset breaker and tested the unit other pole runs at 23.62 on start up its well over 30 amps. When the heater is not going its 4.6 amps. Disassembled the unit and checked for any issues Burt wires etc. found nothing. Look at the heater coils they all looked as they should also ohmed them out and they both tested the same. Suspect the issue is the breaker. This unit it on a 30 amp circuit. When the breaker trips is when the heater cycles. Its not right away its after a few cycles of the heater.
“Brandon was very professional, definitely went above and beyond to diagnose the problem”
Lesley H.