We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF535SWHZ00
Near Crystal, MN 55422
Phillip
Job Details: 09/25/2023
"The complaint is the whole side is not cooling in either section. I found all the fans are running and the compressor and both sections are warm. I pulled the evaporator cover off and found no frost on the evaporator. I pulled the refrigerator out and removed the rear cover. I found someone put a bullet valve on the low side process tube. I put my hose on the valve and opened the valve. The low side pressure was in a 25 inch vacuum. We added 200 psi of nitrogen. I checked ever joint in the back and in the freezer for leaks. After 20 minutes I found no leaks but my pressure had dropped. I pulled a vacuum and then charged the system. The compressor is on and running and the evaporator is getting cold. The refrigerator has a leak internally. Please submit to AHS. The customer did tell me another company was out and also was not able to find a leak and repair it. ; saved tckt , states that autho needed"
We serviced a
WHIRLPOOL WASHER
Model MISSING
Near Crystal, MN 55428
Phillip
Job Details: 09/06/2023
The model number is worn away. The washer would not go into a spin. I found the lid switch was faulty. I jumped the switch and now its working. I quoted for the switch. I replaced the lid switch and tested the washer. Its working good. The agitator dogs are good too.
We serviced a
WHIRLPOOL RANGE
Model WFG361LVQ
Near Crystal, MN 55428
Adam
Job Details: 11/16/2022
Installed new power cord from last diagnosis. Tested all operations and everything is working properly. Installed WP9757891
We serviced a
GE REFRIGERATOR
Model GTE18GTNDRWW
Near Crystal, MN 55428
Adam
Job Details: 07/05/2022
Installed fan from last installed. Now unit is working properly with no noise. ; states that autho needed
We serviced a
GE REFRIGERATOR
Model GTE18GTNDRWW
Near Crystal, MN 55428
Adam
Job Details: 07/01/2022
Units freezer evap fan is making noise a randomly times. Which is common on these units. Quoted property manger blue book for repair. Spoke with tenant to make sure the day works fine also. Schedule appointment for the 6th ordered WR60X31522 evap fan; ordrd 1 WR60X31522 (Evap fan)